{"product_id":"goodman-60k-btu-80-afue-4-ton-blower-motor-furnace-gr9s800604bn-with-install-fort-worth-tx-availability","title":"Goodman - 60k BTU - 80% AFUE - 4 Ton Blower Motor - Furnace GR9S800604BN - with install - Fort Worth TX Availability","description":"\u003ch4 dir=\"ltr\"\u003e\u003cspan\u003e\u003cstrong\u003eWhat's Included:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Goodman GR9S80 furnace\u003cstrong\u003e \u003cspan\u003eoffered by AC of Fort Worth\u003c\/span\u003e\u003c\/strong\u003e delivers reliable heating and energy efficiency, ideal for residential use. With an 80% AFUE rating and durable design, it provides consistent warmth while managing energy costs. Its single-stage gas valve and quiet operation ensure dependable performance and comfort.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes licensed and insured HVAC installation by professionals, along with the Install Kit for a complete setup.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eProfessional Installation:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eRemoval \u0026amp; haul-off of existing equipment\u003c\/li\u003e\n\u003cli\u003eInstallation of new equipment and all included parts\u003c\/li\u003e\n\u003cli\u003eRefrigerant line connection, evacuation \u0026amp; charge to OEM spec\u003c\/li\u003e\n\u003cli\u003eFull system start-up, airflow check \u0026amp; operational testing\u003c\/li\u003e\n\u003cli\u003ePermit pulled and permit fees paid with the local jurisdiction\u003c\/li\u003e\n\u003cli\u003eFinal inspection and job-site clean-up\u003c\/li\u003e\n\u003cli\u003ePerformed by a licensed, insured HVAC contractor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eFurnace Kit:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas line\u003c\/strong\u003e gas flex hose, gas pipe fittings (nipples, unions, shut-off, drip leg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVenting\u003c\/strong\u003e flue pipe \u0026amp; elbow set for furnace exhaust\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrainage \u0026amp; PVC\u003c\/strong\u003e P-trap, full PVC fittings kit (couplings, elbows, tee, adapters)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eNot Included:\u003c\/h4\u003e\n\u003cp\u003eThis listing covers the equipment and standard installation scope above. The following items are \u003cstrong\u003enot included\u003c\/strong\u003e unless specifically listed on your written invoice or estimate:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical panel upgrades\u003c\/strong\u003e or new breakers beyond the standard disconnect\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuctwork\u003c\/strong\u003e modifications, repairs, replacement, or new runs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNew refrigerant line set\u003c\/strong\u003e (existing line set is reused when in good condition)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondenser pad re-pour, raised platform, or hurricane tie-downs\u003c\/strong\u003e (standard composite pad is included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondenser relocation\u003c\/strong\u003e to a new exterior position\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCrane or rooftop rigging\u003c\/strong\u003e for difficult equipment access\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas line\u003c\/strong\u003e extension, re-routing, or new gas line deployment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensate drain line\u003c\/strong\u003e rework beyond the immediate connection at the unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat\u003c\/strong\u003e upgrades (standard thermostat reuse only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAsbestos abatement\u003c\/strong\u003e, mold remediation, or hazardous material handling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarpentry, drywall, paint, or flooring\u003c\/strong\u003e repair after installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf any of the above are needed for your home, our technician will assess on-site and provide a written change-order quote before any additional work begins. Nothing extra is charged or performed without your written approval.\u003c\/p\u003e\n\u003ch4\u003e5-Year Labor Warranty:\u003c\/h4\u003e\n\u003cp\u003eLabor is covered for \u003cstrong\u003e5 years\u003c\/strong\u003e from the date of installation. If a covered defect related to our installation causes a failure, we return at no charge for diagnosis and labor. Parts replacements are handled under the OEM parts warranty (10 years when registered). Excludes maintenance, filter changes, customer-caused damage, and acts of nature. Full terms on the Warranty \u0026amp; Guarantee page.\u003c\/p\u003e\n\u003ch4\u003eKey Features:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e80% AFUE Efficiency:\u003c\/strong\u003e Provides consistent, energy-efficient heating to reduce operating costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-Stage Heating:\u003c\/strong\u003e Ensures reliable warmth with simple performance year-round.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet and Smooth Performance:\u003c\/strong\u003e Reduces noise for enhanced indoor comfort.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Steel Cabinet:\u003c\/strong\u003e Protects internal components and extends furnace life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Installation Options:\u003c\/strong\u003e Compact size and multiple airflow configurations allow versatile installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Goodman GR9S80 furnace\u003cstrong\u003e \u003cspan\u003eoffered by AC of Fort Worth\u003c\/span\u003e\u003c\/strong\u003e is a stable, cost-effective choice for homeowners seeking comfort and efficiency. When paired with Goodman air conditioning or heat pump systems, it offers a complete heating and cooling solution year-round.\u003c\/p\u003e\n\u003cdiv title=\"Page 8\" class=\"page\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv title=\"Page 8\" class=\"page\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv title=\"Page 8\" class=\"page\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv title=\"Page 8\" class=\"page\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 102.37825%; height: 308px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003cth class=\"col label\" scope=\"row\" style=\"width: 50.265487%; height: 18px; text-align: left;\"\u003eFurnace Model\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Model\" style=\"width: 48.318584%; height: 18px;\"\u003e\n\u003cp class=\"p1\"\u003eGR9S800604BN\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003cth class=\"col label\" scope=\"row\" style=\"width: 50.265487%; height: 18px; text-align: left;\"\u003eCapacity (BTU)\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Bundle Cooling Capacity\" style=\"width: 48.318584%; height: 18px;\"\u003e60K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003cth class=\"col label\" scope=\"row\" style=\"width: 50.265487%; height: 18px; text-align: left;\"\u003eStages\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Bundle Cooling Efficiency (SEER2)\" style=\"width: 48.318584%; height: 18px;\"\u003eSingle-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 50.2655%; text-align: left;\" scope=\"row\"\u003eCabinet Size\u003c\/th\u003e\n\u003ctd style=\"width: 48.3186%;\"\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 50.2655%; text-align: left;\"\u003eAirflow Measurement (CFM)\u003c\/th\u003e\n\u003ctd style=\"width: 48.3186%;\"\u003e1,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003cth style=\"width: 50.265487%; text-align: left;\" scope=\"row\" class=\"col label\"\u003eAFUE\u003c\/th\u003e\n\u003ctd style=\"width: 48.318584%; height: 18px;\" data-th=\"Refrigerant\" class=\"col data\"\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 50.2655%; text-align: left;\" scope=\"row\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"width: 48.3186%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003eUpflow \/ Horizontal Left\/Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 69px;\"\u003e\n\u003cth style=\"width: 50.265487%; text-align: left; height: 69px;\"\u003eWarranty\u003c\/th\u003e\n\u003ctd style=\"width: 48.318584%; height: 69px;\"\u003e\n\u003cp\u003e\u003cspan\u003e10 Year Parts, 10 Year Furnace\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e(When Registered with OEM)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch5 class=\"layoutArea\"\u003e\u003cstrong\u003eRESOURCES\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003ctable width=\"100%\" style=\"height: 105px; width: 101.462523%;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"height: 18px; width: 35.100549%;\"\u003e\u003cstrong\u003eFurnace\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px; width: 35.100549%;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0798\/1311\/6133\/files\/Goodman_Furnace_Warranty.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eLIMITED WARRANTY\u003c\/span\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 35.100549%;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0798\/1311\/6133\/files\/Goodman_GR9S80_Product_Specs.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003ePRODUCT SPECS\u003c\/span\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eDisclaimer for Low NOx Furnace Compliance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCertain regions, including California, have strict Low NOx (Nitrogen Oxides) emission regulations for furnaces. Customers must ensure compliance with all local, state, and federal rules before purchasing and installing a furnace.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":48955756052709,"sku":"ALC-GM-FN-60K-80-1S-UH-01","price":3122.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0798\/1311\/6133\/files\/acFortworth_Goodman_Furnace.png?v=1777674984","url":"https:\/\/acfortworth.com\/products\/goodman-60k-btu-80-afue-4-ton-blower-motor-furnace-gr9s800604bn-with-install-fort-worth-tx-availability","provider":"AC Fort Worth LLC","version":"1.0","type":"link"}